The equipment in the new On Line INEO range is built in an N+X parallel redundancy arrangement, DSP control technology, high input and output power factor. Wide input voltage window for energy saving, ECO mode. They are the ideal solution for servers, banks, industrial equipment, IT equipment, communication systems and other connectivity equipment that require protection.
– SENSICHARGER battery charging system – Emergency EPO system – Green design, get more savings energetic – THDI <3% –Cold start – Possibility of extended autonomy – Possibility of disposition growth redundant parallel (up to 4 units) |
TYPICAL APPLICATIONS– Automated doors |
FORMATTower with adjusted dimensions to occupy little ENTRANCES AND PORTS- USB port |
GENERATING SETFully compatible with electric generators EXTRA COMPONENTS– Hermetic lead batteries |
TECHNICAL SPECIFICATIONS
MODEL | INEO 1000 | INEO 2000 | INEO 3000 |
Capacity | 1000VA/1000W | 2000VA/2000W | 3000VA/3000W |
Phase | Phase + Neutral | ||
STARTERS | |||
Rated voltage | 200/208/220/230/240Vac | ||
Operating voltage range | Transferencia tensión baja 160Vac±5%@100%~80%carga; 140Vac±5%@80%~70%carga;120Vac±5%@70%~60%carga; 110Vac±5%@60%~0%carga (Temp.Ambient <35ºC)
Retorno por línea baja 175Vac±5%@100%~80%carga; 155Vac±5%@80%~70%carga;135Vac±5%@70%~60%carga; 125Vac±5%@60%~0%carga(Temp. Ambiente.<35ºC) High voltage transfer 300Vac±5% High line return 290Vac±5% |
||
Input voltage range | 55~150Vac or 110~300Vac@60%load, 80~145Vac or 160~300Vac@100% load | ||
Frequency range | 40 ~ 70Hz | ||
Power factor | 0.99 | ||
group entry | Support | ||
PROJECTION | |||
Output voltage | 200/208/220/230/240Vac | ||
Power factor | 1.0 | ||
voltage regulation | ± 1% | ||
Frequency | Line mode (sync range) 47~53Hz or 57~63Hz
Battery mode 50/60 (±0.1)Hz |
||
crest factor | 0,1256944444 | ||
Harmonic distortion (THDv) | ≤2% THD (Linear Charge) ≤4% THD (Non-linear Charge) |
||
Waveform | Pure Sine | ||
transfer time | AC mode <-> Batt. null
Inverter <-> Bypass 4ms (Typical) |
||
EFFICIENCY | |||
AC mode | 88% | 92% | 92% |
BATTERY | |||
Autonomy time | Standard except in long autonomy models | ||
Typical Recharge Time (Standard Model) | Recharges to 90% in 4 hours | ||
Charging voltage | 27.4VDC±1% 41.1VDC±1% 54.7VDC±1% 82.1VDC±1% 82.1VDC±1% 109.4VDC±1% | ||
Charge current (max.) | 1A 12A 1A 12A 1A 12A | ||
Line mode Battery mode |
Temp. environment <35ºC 105%~110%: UPS transfers to bypass after 10' 110%~130%: UPS transfers to bypass after 1 minute 105%~110%: UPS transfers to bypass after 10' 110%~130%: UPS transfer to bypass after 1 minute 35ºC< Temp. Atmosphere <40ºC 105%~110%: UPS transfers to bypass after 1 minute 110%~130%: UPS transfers to bypass after 5' >130%: UPS transfer to bypass immediately 105%~110%: UPS transfer to bypass after 1 minute 110%~130%: UPS transfers to bypass after 5' >130%: UPS transfers to bypass immediately |
||
Short circuit | maintains the system | ||
Overheating | Line Mode: Transfer to bypass; Backup mode :Immediate shutdown | ||
Low battery | alarm and shutdown | ||
EPO (optional) | immediate shutdown | ||
Audible and visual alarms | Line Fail, Low Battery, Overload, System Fail | ||
communication interface | USB, RS232, SNM card, P Relay card (optional) | ||
ENVIRONMENTAL CONDITIONS | |||
Operating temperature | 0~40ºC | ||
Storage Temperature | 25ºC~55ºC | ||
humidity range | 20~90% RH@0~40ºC (Non-condensing) | ||
Altitude | |||
Noise level | Less than 50dBA at 1 Meter |
MODEL | INEO 5000 | INEO 6000 | INEO 8000 | INEO 10000 |
Capacity | 5kVA/5kW | 6kVA/6kW | 8kVA/8kW | 10kVA/10kW |
STARTERS | ||||
Rated voltage | 220/230/240Vac | |||
Operating voltage range | 120~276Vac | |||
Frequency range | 50Hz:45~55Hz;60Hz;54~66Hz (auto ajustable) | |||
Power factor | ≥0.99 | |||
Bypass voltage range | Max. Voltage: 220V:+25% (optional +10%, +15%, +20%) Bypass Voltage Range 230V: +20% (optional +10%, +15%) 240V: +15% (optional +10%) Min. Voltage: -45% (optional -20%, -30%) Max. Voltage: 220V:+25% (optional +10%, +15%, +20%) Bypass Voltage Range 230V: +20% (optional +10%, +15%) 240V: +15% (optional +10%) Min. Voltage: -45% (optional -20%, -30%) Max. Voltage: 220V:+25% (optional +10%, +15%, +20%) Bypass Voltage Range 230V: +20% (optional +10%, +15%) 240V: +15% (optional +10%) Min. Voltage: -45% (optional -20%, -30%) Max. Voltage: 220V:+25% (optional +10%, +15%, +20%) Bypass Voltage Range 230V: +20% (optional +10%, +15%) 240V: +15% (optional +10%) Min. Voltage: -45% (optional -20%, -30%) |
|||
Bypass Frequency Range | Frequency Protection Range: ±10% | |||
ECO mode range | Same as Bypass | |||
Harmonic distortion (THDi) | <3% (100% linear load) | |||
group entry | supports | |||
PROJECTION | ||||
Output voltage | 220/230/240Vac | |||
Power factor | 1.0 | |||
voltage regulation | ± 1% | |||
Frequency | Line mode ±1%/±2%/±4%/±5%/±10% of frequency range (optional)
Battery mode 50/60 (±0.1) Hz |
|||
crest factor | 3:1 | |||
Harmonic distortion (THDv) | 2% with linear load 5% with non-linear load |
|||
Efficiency | >93% | |||
DRUMS | ||||
battery voltage | ±96/108/120Vdc (Adjustable) | |||
Typical recharge time | 6~8 hours (to reach 90% charge) | |||
Charging current | 1A | |||
SYSTEM CARACTERISTICS | ||||
transfer time | Main to Battery: 0ms; Main to bypass: 0ms Main to Battery: 0ms; Main to Bypass: 0ms |
|||
Overload | Line mode Load ≤110%: 10min, ≤130%: 1 min, >130% Go to Bypass mode immediately
Bypass Mode 63A (Switch) 80A (Switch) |
|||
Short circuit | Protect the System | |||
Overheating | Line Mode: Step to Bypass; Batt. Mode: Immediate shutdown of the UPS | |||
Low battery | alarm and shutdown | |||
Self-diagnosis | On power up and software control | |||
Battery | Advanced Battery Management | |||
battery voltage | ±96/108/120Vdc (Adjustable) | |||
Typical recharge time | 6~8 hours (to reach 90% charge) | |||
Charging current | 1A | |||
SYSTEM CARACTERISTICS | ||||
transfer time | Main to Battery: 0ms; Main to bypass: 0ms Main to Battery: 0ms; Main to Bypass: 0ms |
|||
Overload | Line mode Load ≤110%: 10min, ≤130%: 1 min, >130% Go to Bypass mode immediately | |||
Bypass mode | 63A (Switch) | 80A(Switch) | ||
Short circuit | Protect the System | |||
Overheating | Line Mode: Step to Bypass; Batt. Mode: Immediate shutdown of the UPS | |||
Low battery | alarm and shutdown | |||
Self-diagnosis | On power up and software control | |||
Battery | Advanced Battery Management | |||
Audible and visual alarms | Line Fault, Low Battery, Overload, System Fault | |||
LED and LCD displays | Line Mode, Batt. Mode, Eco mode, Bypass Mode, Low Battery Voltage, Overload and UPS Failure | |||
LCD Display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Input Voltage battery, ambient temperature and autonomy time |
|||
communication interface | RS232, USB, SNMP Card (optional), Parallel Card (optional), Relay Card (optional) | |||
PHYSICAL | ||||
Dimensions WxHxD (mm) | 191x660x460 | 191x660x460 | 191x660x460 | 191x660x460 |
Net weight / kg) | 65 | 75 | 83 | 90 |
ENVIRONMENTAL CHARACTERISTICS | ||||
Operating temperature | 0ºC~40ºC | |||
Storage Temperature | -25ºC~55ºC | |||
humidity range | 0~95% (Non-condensing) | |||
Altitude | ||||
Noise level | ||||
REGULATION | ||||
Security | IEC/EN62040-1, IEC/EN60950-1 IEC/EN62040-1, IEC/EN60950-1 |
|||
EMC | IEC/EN62040-2, IEC/61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC1000-4-8 |